(C) System Exclusive Data Format
Program Dump
Byte No Value Parameter Description/Range
0 $F0 Exclusive Status SysEx transfer start
1 $3E Manufacturer ID Waldorf Electronics GmbH
2 $0B Model ID Pulse ID
3 0...126 Device ID Equivalent to the global parameter device ID
4 $00 Function Code Dump type, in this case program dump
5 0...99 Program No P.1 ... P.99 / P.rn
6 16...112 Osc1 Semitone -48...+48
7 0...127 Osc1 Tune -32...+31
8 0...2 Osc1 Shape 0: Pulse
1: Sawtooth
2: Triangle
9 0...127 Osc1 PW 0...127
10 16...112 Osc2 Semitone -48...+48
11 0...127 Osc2 Tune -32...+31
12 0...3 Osc2 Shape 0: Pulse
1: Sawtooth
2: Triangle
3: Cross Modulation
13 0...127 Osc2 PW 0...127
14 0...1 Osc2 Keytrack 0: off
1: on
15 0...1 Osc2 Sync 0: off
1: on
16 16...112 Osc3 Semitone -48...+48
17 0...127 Osc3 Tune -32...+31
18 0...2 Osc3 Shape 0: Pulse
1: Sawtooth
2: Triangle
19 0...127 Osc1 Level 0...127
20 0...127 Osc2 Level 0...127
21 0...127 Osc3 Level 0...127
22 0...127 Noise Level 0...127
23 0...127 LFO1 Speed 0...127
24 0...7 LFO1 Shape 0: Sine
1: Triangle
2: Sawtooth
3: Pulse
4: Sample & Hold
5: Triangle Sync
6: Sawtooth Sync
7: Pulse Sync
25 0...127 LFO2 Speed 0...127
26 0...127 LFO2 Delay 0...127