Waldorf Pulse Manual de usuario Pagina 67

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 78
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 66
User’s Manual Pulse • PulsePlus
67
Global Parameter Dump
Byte No Value Parameter Description/Range
0 $F0 Exclusive Status SysEx transfer start
1 $3E Manufacturer ID Waldorf Electronics GmbH
2 $0B Model ID Pulse ID
3 0...126 Device ID Equivalent to the global parameter device ID
4 $08 Function Code Dump type, in this case global parameter dump
5 0...99 Startup Program P.1 ... P.99 / P.rn
6 54...74 Master Tune 430...450 Hz
7 0...127 Control X 0...127
8 0...16 MIDI Channel 0: omni
1...16: Channel 1-16
17: A. omni
18...33: A.1...16
9 0...126 Device ID 0...126
10 CHK Checksum Checksum via bytes 5 through 9, bit 7 cleared
11 $F7 EOX End of SysEx message
CV/Gate Interface Parameter Dump
Byte No Value Parameter Description/Range
0 $F0 Exclusive Status SysEx transfer start
1 $3E Manufacturer ID Waldorf Electronics GmbH
2 $0B Model ID Pulse ID
3 0...126 Device ID Equivalent to the global parameter device ID
4 $08 Function Code Dump type, in this CV/Gate Interf. parameter dump
5 0...16 CV/Gate Channel 0: off
1...16: 1...16
6 0...127 CV In Adjust -64...+63
7 0...72 CV In Transpose -36...+36
8 0 reserved
9 0...1 Gate In Polarity 0: up
1: down
10 0...3 Gate Out Polarity 0: 5L
1: 12L
2: 5H
3: 12H
11 0...1 CV Out Curve 0: logarithmic
1: linear
12 0...127 CV Out Adjust -64...+63
13 0...127 CV Out Offset -64...+63
14 0 reserved
15 CHK Checksum Checksum via bytes 5 through 14, bit 7 cleared
16 $F7 EOX End of SysEx message